Model NO.: QDZH35G
Refrigerant Type: Freon
Type: Piston
Power Source: AC Power
Configuration: Stationary
Application: High Back Pressure Type, Low Back Pressure Type
Mute: Mute
Trademark: sikelan
Transport Package: Carton and Pallet
Specification: QDZH35G
Origin: China
HS Code: 8414301100
1-MAIN FEATURE:
High efficiency
Low vibration
Good reliability
Experienced staff ensure produce of the compressors with good quality.

2-SIMPLE SPECIFICATION:
1)QDZH35G, DC series, use R134a refrigerant;
2)Voltage application 12/24VDC;
3)Cooling type: FC;
4)Application: Low Back Pressure;
5)Max Cooling Capacity: 100W;
 
Serial Model Displacement (cm3) Rotate Speed       (rpm) Capacity COP EER Oil charge Cooling Type Power Supply Certificate
-23.3ºC (ASHRAE)
W Kcal/h Btu/h W/W Btu/W.h ml
L QDZH25G 2.5 2000 43.0 37.2 146.0 1.08 3.68 130 FC 12/24V (DC) CE
2500 53.0 45.8 186.0 1.05 3.58
3000 62.0 53.5 211.0 1.06 3.62
3500 72.0 62.2 245.0 1.04 3.55
QDZH30G 3.0 2000 52.0 44.6 176.0 1.05 3.58
2500 64.0 55.0 217.0 1.05 3.58
3000 75.0 64.3 254.0 1.06 3.62
3500 87.0 74.7 295.0 1.04 3.55
QDZH35G 3.5 2000 60.0 51.9 204.6 1.08 3.68
2500 73.0 63.1 248.9 1.07 3.65
3000 86.0 74.4 293.2 1.06 3.62
3500 100.0 86.5 341.0 1.05 3.58
QDZH43G 4.3 2000 80.0 69.1 273.0 1.15 3.92
2500 96.0 82.9 327.6 1.2 4.09
3000 115.0 99.4 392.4 1.25 4.27
3500 138.0 119.2 470.9 1.25 4.27
MK QDZH50G 5.0 2000 87.0 75.2 296.8 1.17 3.99 180
2500 104.0 89.9 354.8 1.13 3.86
3000 130.0 112.3 443.6 1.35 4.61
3500 163.0 140.8 556.2 1.2 4.09
QDZH65G 6.5 2000 120.0 103.6 409.4 1.2 4.09
2500 150.0 129.6 511.8 1.2 4.09
3000 180.0 155.5 614.2 1.2 4.09
3500 210.0 181.4 716.5 1.2 4.09


3-CERTIFICATE: CE.

4-STORAGE CONDITION:
1)Compressor should be stored in a dry and drafty place
2)Compressor should not be tilted or inverted in storage, transportation and
Installation; Collision should be avoided.
3)Rubber plugs should not be pulled out from discharge tube before installation so
As to avoid impurity and humidity. During the installation, the rubber plugs of
Discharge tube should be pulled out at first, then the rubber plugs of process
Tube, and the rubber plugs of process suction tube at last. The installation should
Be completed within 10 min after that.
4)The accessories (eg. Starter, thermal protection etc. ) are nor installed into
The compressor while delivery, but in the accessory case. Be sure to select the
Corresponding starter and thermal protection models rightly.

Chaff Cutter

Chaff Cutter,Chaff Cutter Machine,Electric Chaff Cutter,Mini Chaff Cutter

Hunan Nongyou Machinery Group CO.,LTD , https://www.ricemill.nl