Pump installation methods and precautions:

First, the installation method and sequence of the pump:

1, the unit on the foundation buried in the bolt, between the base and the base, with a pair of wedge pad with calibration.

2, release the coupling large, respectively, with the spirit level on the pump shaft and base, by adjusting the wedge pad, the unit level correction, appropriate tightening anchor bolts to prevent ambulation.

3, the correction of the concentricity of the pump shaft and the motor shaft, the outer diameter of the shaft in the joint, allowing the deviation of 0.1 mm; two coupling plane clearance should be guaranteed 2 to 4 mm, (small pump to take a small value) Tolerance of 0.3 mm.

4, pick up the pipeline and determine the direction of motor rotation, then connect the coupling, and then check the concentric ax again axis.

5, the actual test run in the unit after 2 to 3 hours for the final inspection, if no bad phenomenon, then that the installation of qualified. Check the bearing during the trial temperature and vibration conditions are as follows: Imported pump valve

6, in the installation process, in order to prevent debris falling into the machine, all the holes of the unit should be covered.

7, to prevent debris in the pipeline into the pump, the newly installed pipeline, the pump should be installed gel filter, the effective cross-section should be greater than 2 to 3 times the suction tube cross section. Imported pump.

Second, the pump should be noted in the installation process:

1, the installation of the pump is good or bad, the smooth operation of the pump and the service life has a very important impact, so the installation and calibration work must be carefully carried out, not sloppy.

2, pump suction pipe installation height, length and diameter should meet the calculated value, and strive to be brief, reduce unnecessary losses (such as elbows, etc.); And to ensure that the pump does not exceed its allowance NPSH.

3, the pump suction and discharge pipe should have a bracket. Pump is not allowed to withstand the load on the pipeline.

4, the location of the installation of pumps should be spacious enough to facilitate maintenance work.

This article Keywords: pump

Pharmaceutical Preparations

The so-called Pharmaceutical Intermediates are actually some chemical raw materials or chemical products used in the process of drug synthesis. This kind of chemical product does not require a pharmaceutical production license and can be produced in an ordinary chemical plant. As long as it reaches a certain level, it can be used for the synthesis of pharmaceuticals.

Our country needs more than 2,000 kinds of raw materials and intermediates for chemical industry every year, and the demand is over 2.5 million tons. After more than 30 years of development, the chemical raw materials and intermediates required for the country's pharmaceutical production can basically be matched, and only a small part of it needs to be imported. Moreover, due to my country's abundant resources and low raw material prices, many intermediates have been exported in large quantities.

On the one hand, product updates in this field are fast. Generally, after a product has been on the market for 3 to 5 years, its profit margin will drop significantly. This forces companies to continuously develop new products or continuously improve production processes in order to maintain a high production profit; on the other hand, due to the production profit of pharmaceutical intermediates Higher than chemical products, the production process of the two is basically the same, so more and more small chemical companies have joined the ranks of producing pharmaceutical intermediates.

Pharmaceutical Preparations,Propylene Glycol Monomethyl Ether,Digestion Improvemen Smart Acid,Smart Acid Organic-Salt Compound Acidifier

Sunrise Group Corporation , https://www.sunriseindust.com