1. First check everywhere bolts loose, the power cord and the plug is intact, the motor insulation resistance should be greater than 2 megohm. 2 In order to prevent electric shock accidents, it is necessary to install the corresponding safety measures such as earth leakage circuit breaker or electric shock safety device, and to conduct reliable grounding 3. The working voltage of the pump should be used within the range of +5% and -12% of the rated voltage, otherwise the service life of the motor will be shortened or burned out. Electric pump as far away from the power supply, power transmission line should be appropriate bold, otherwise it will use the voltage drop and can not run. 4 Close the power switch, the pump idle for about 2 minutes to see the start, the operation is normal, the steering is correct. 5 Fix the pump body with steel pipe or rubber tube (must not be too soft to avoid suction), connect the inlet and the bottom valve. The bottom valve must be placed perpendicular to the horizontal surface and above the water bottom 30cm to avoid sucking the sediment. 6. Clean water centrifugal pump to use and automatically suck the pump for the first time before use, it is necessary to fill the tank water, electricity can not automatically after a few seconds out of water, the future does not require irrigation. 7. Since the pump and automatic self-priming clear water pump tube for the first time before use, it is necessary to fill the water tank filled with water, electricity can not automatically after a few seconds out of water, the future does not require irrigation. 8. Use, the motor should be kept dry, pay attention to the water level down, the bottom valve can not be exposed outside the water. When the temperature is below 4 â—‹ C. Antifreeze should be done, so as not to freeze the pump body. 9 If it is not used for a period of time, drain the water in the pump (self-priming pump and automatic pump to drain the water in the water tank), scrub the main parts clean, apply anti-rust oil and keep it in a ventilated and dry place for future use.