1 reason analysis (1) motor power, operating current, heat.
(2) fewer fan blades, resulting in a small amount of wind.
(3) low speed fan, wind pressure, the amount of wind is small.
(4) The voltage of the bus where the vacuum pump motor is located is 380V. Due to the voltage drop of the cable and the uneven distribution of the load, the actual voltage applied by the motor is only 365V, which causes the running current to be large due to the low voltage.
(5) motor with dust, oil, reducing the cooling capacity.
2 Countermeasures Motor power, speed and vacuum pump match, can not be changed. Fan mounted on the motor shaft, the motor speed determines the fan speed, it can not be replaced. Although increasing the number of fan blades can play a role, but the increase in the number of blades, the dynamic balance is not easy to find, such as finding is not good, will cause increased motor vibration.
(1) Lengthen the original fan cover 40cm, install a fan with the same diameter inside the axial fan, axial fan motor power 850W, speed 1489r / min, voltage 380V. The original fan to keep. Axial flow fan set up all the way to power control, axial fan and the main motor without a chain. After the start of the vacuum pump to start the axial fan operation in time, the vacuum pump outage after 30min out of axial fan, so that the main motor is fully cooled;
(2) Regularly remove the dust on the motor to keep the motor heat sink clean and increase its cooling capacity;
(3) The bus where the vacuum pump voltage is adjusted to 400V.
3 Effect (1) As the axial fan speed is high, the wind pressure air volume, cooling effect is greatly enhanced in the same ambient temperature and load current, the main motor temperature dropped 12 ℃. Summer main motor temperature no longer exceeded.
(2) slow down the insulation aging of the main motor, extending its service life.
(3) Axial fan can be artificially controlled, the main motor is out of service, the axial fan can still run, the main motor can be fully cooled.
(4) After the voltage is adjusted, the operating current of the diaphragm pump is reduced to 210A, and the calorific value is relatively reduced.
(5) Try to balance the load distribution of the 2-phase busbar to prevent over-voltage drop of some busbar due to overload.
More Keyword Search: Vacuum Pumps
Cork Gasket Making,Gasket Cutter Machine,Cork Gasket Cutting Machine,Cork Gasket Cutting Tool
Jinan Zhuoxing Intelligent Technology Co., Ltd. , https://www.zhuoxingcutting.com