How to install solenoid valve to use?

Solenoid valve installation use: 1, before installation should refer to the product manual, whether it meets your use requirements. 2, the pipeline should be washed before use, the media should be installed clean filter to prevent impurities impede the normal operation of the solenoid valve. 3, the solenoid valve is generally one-way work, can not be installed, the arrow on the valve is the fluid direction of the pipeline must be consistent. 4, the general level of solenoid valve installation, the coil up vertically, some products can be any installation, but the best when possible vertical conditions to increase the service life. 5, Solenoid valve in the ice should be re-working place heat treatment, or set insulation measures. 6, solenoid lead (connector) connected, you should confirm the firmness, contact the electrical components should not shake the contact, loose will cause the solenoid valve does not work. > Import pump 7, continuous to produce the work of the solenoid valve, the best bypass, easy maintenance, does not affect the production. 8, after a long time to disable the solenoid valve, condensate should be cleared after the easy-to-use; washable when the parts should be put in order to restore the original state installed. This article Keywords: solenoid valve

Relationship between dielectric loss and temperature and frequency of fluorphlogopite

The main performance of fluoride crystal mica used in the field of electrical insulation: The 13th Institute of Shijiazhuang, the CLP Group and the Second Aviation Academy of the Air Force

Institute of Fluid Physics, China Academy of Engineering Physics (Nine Institute of Mianyang), Institute of High Energy Physics, Chinese Academy of Sciences, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, National Synchrotron Radiation Laboratory, Hefei Institute of Physical Chemistry, Chinese Academy of Sciences , 50th Institute of China Electronics Technology Group Corporation (Shanghai), 23 Institute of the Second Institute of China Aerospace Science and Industry Corporation, Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing Institute of Radiometrics, 12th Institute of China Electronics Technology Group (Semiconductor 12).

Mica Insulation Pad

Mica Insulation Pad,Insulation Pad,Mica Insulation Film,Mica Insulation Material

Changchun City Taiyuan FluorphlogopiteCo. Ltd. , https://www.micaslice.com