The project as a whole indicates that all equipment and fire fighting systems are linked, requiring all equipment to be able to run offline in the event of a network failure and all systems fail when a fire signal is input, the elevator is not controlled, the barrier is opened, the access is turned on, and water control is automatically turned off.
Reserved Smart One Card Other Subsystem Interface Reserved English Version Software Interface Reserved Software SDK Interface to Campus One Card Management Software To facilitate the access of other systems, the card adopts an open architecture.
One card, one library, one software, one platform, it is not allowed to use multiple manufacturers, multiple softwares, multiple card dispensers, to integrate on one card, so that the true meaning of the intelligent management card, use the card because the elevator belongs to special equipment , Suppliers must provide real and effective special equipment test reports. Read heads look beautiful and generous with capacitive touch password keyboard. Suggested glass material. Closed management mode Video intercom system using pure digital TCP/IP mode Water control, electronic control , intelligent newspaper boxes in offline mode management center system <br> <br> overall system requirements:
One card, one library, one software, one platform, it is not allowed to use multiple manufacturers, multiple softwares, multiple card issuers, to integrate on one card, so that the true meaning of the intelligent management card, using a card.
Technical specifications of major equipment:
Power supply: external DC12V ± 5%;
Power input power: 2W;
Card reader module (Mifare® core module) model: MFRC500;
Working environment temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing);
The card type used is Miare® 1 card;
Reading and writing card distance: 0 ~ 5CM;
Reader and host computer communication: standard RS-232 asynchronous serial communication;
Communication parameters: baud rate: 115200bps; communication format: 1 start bit; 8 data bits; 1 stop bit; no parity bit; handshake: software handshake.
Access Control System System Function System Architecture: The network status can be operated offline in the event of a failure, and the fire-fighting linkage can be used to report the loss of cards.
Access control read head adopts capacitive touch password keyboard (unit intercom host uses embedded access control).
Households use a split plan.
Optional image capture and electronic map function, when the card is swiped, the image can be captured and saved, which can prevent the generation of swiping cards. (Internet access required)
It can flexibly set the cardholder's right to open the door, open the door, and open the door in the area to support multiple door opening methods: password, swipe card, remote door opening (networking required)
Can support multiple conditions and flexible combination of query access records, sort the report data in a different order, support for report data printing and export to the file function power lock power-down status can be key to open the door can be with multi-Olympic elevator / parking lot / channel / consumer / smart Card Main Equipment Specifications Operating Voltage: DC12V/1A
Working environment: -30°C-75°C
Communication method: RS485
Support card type: IC card, CPU card, etc. Intelligent Parking System Function Description Kernel uses ARM chip, I/O, control, etc. Integrated into a PCB board Nested partition management mode With remaining parking space Display temporary vehicle Automatic card output Anti-theft car entrance control machine with automatic card-out function (card out of abnormal situation when the card can be automatically recovered to prevent the loss of the card), unattended can be used to achieve automatic transfer of vehicles in and out images, capture, manual comparison of temporary card charges set Flexible, universal, support for multiple charging methods and elevator/attendance/access control/consumption/channel, etc. Smart Card Main Equipment Specifications Card Format: IC Card Power Supply: DC12V
Reading distance: 0-5CM
Working temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing)
The function of the intelligent consumption system requires that the consumption machine has the function of automatically recognizing "pseudo-cards", holding fake cards, fake cards, and those who have lost the cards, and the consumption machines will not be consumed.
Realize daily, monthly, yearly, and certain stages of the restaurant's daily report and monthly report records in detail. Various data can be seen at a glance at the desktop, and the hanging type can be converted to smart card main equipment technologies such as elevators/access control/consumers/channels. Parameter card format: IC card power supply: DC12V
Reading distance: 0-5CM
Working temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing)
Intelligent water control system function requires an integrated water control machine with electric valve, pulse water meter, lithium battery, controller integrated design, novel appearance, easy installation, tamper, anti-theft;
The operation is simple and does not require all kinds of complicated settings. One card, one card, the card is the withholding fee, the measurement is real-time and easy to use. After the card is deducted from the pre-charged water, the valve is opened and the valve is closed after the purchase of water.
Only single-cell lithium battery is used for power supply, and no external power supply is required for installation. It is convenient to replace the battery and is suitable for installation and use in dormitories and homes.
Battery box and body can be sealed to prevent malicious water theft;
When the amount of purchased water is used up, or when the battery is low, it prompts and automatically closes the valve;
Energy-saving design, using ultra-low-power chips, key trigger work, automatic sleep, effectively extending battery life;
Anti-theft, explosion-proof design, base table, base valve using high quality copper;
Anti-magnetic attack design, detecting magnetic interference can automatically close the valve;
The adjustable direction of the liquid crystal display makes it convenient for the user to view and display abundant information such as water consumption, remaining water amount, battery power, and valve switch status.
The equipment supports the use of cards to collect the remaining amount of water to the management software for the convenience of refunds and form changes.
Can be connected with elevators/access control/consumers/channels, etc. Smart Card Main Equipment Specifications Card Format: IC Card Issuer Capacity: Unlimited Operating Distance: >20mm
Working frequency: 13.56M
Read and write time: <1 second measurement accuracy: 1L
Data retention time: 10 years Battery life: 5 years Operating voltage: DC 3.7V
Ambient temperature: -5°C--50°C
Attendance intelligent management system (optionally equipped with source 2.4G remote automatic attendance system)
System function 1 Attendance system and access control system share employee basic database;
2 The employee's access record on the attendance machine is uploaded to the attendance computer and used directly for attendance;
3 has a password key function 4 with LCD display;
5 Query reports can be freely converted to EXCEL, TXT and web forms, user-friendly attendance reports and financial hooks, and remote web-based attendance reports sent over the Internet;
6 can print the attendance master list and schedule for any period of time, the item to be printed can be set by the user;
7 In the attendance overtime setting, you can freely set overtime start, end time, and overtime timing (usually the default is 1 overtime every half hour, the user can also be set arbitrarily) so that the employee can automatically read the overtime hours by swiping the card. recording. ;
8 Software records Store information such as the card number, job number, date and time, and validity of each employee's card attendance.
9 Optional image monitoring capture software, you can capture and save the image when swiping the card, the center management computer can display the swipe card image in time to prevent the card swiping or illegal card swiping. ;
10 can be with Doo elevator / parking lot / access control / consumer / etc. smart card major equipment technical indicators Power supply: AC220/50H
Working environment temperature: -35 degrees - +70 degrees Relative humidity: <95% non-condensing brushing distance: 5-10CM
Communication Interface: RS485 Optional TCP/IP
Support card types: IC card, CPU card, etc. Elevator IC card intelligent control system (for schools with elevators to prevent students from quaking eggs)
System functions • Control personnel in the elevator school box enter a specific floor. Control the access of cardholders to specific floors that are allowed in and out to prevent random access to all floors to ensure safety;
• The system and the elevator itself are passively connected. The two are completely isolated and will not affect the original performance of the elevator.
• Full port over-current, over-voltage, lightning protection, back pressure protection, instant over-voltage short-circuit protection, safe, stable and reliable;
• With section increment, delete, query card number and floor setting, you can set the elevator control such as holiday time permission setting by time;
• With time zone control: The system is opened for a certain period of time, controlled for a certain period of time, so that the elevator automatically runs according to regulations;
• Operation mode: Single-layer card (owner's card) Holder's credit card direct access. No need to press key; Multi-layered card (such as health management of aunts and patrolling security) after the user has swiped the card, it must be recorded according to the card. Permission keys to arrive; optional pure glass capacitive touch password keyboard, to achieve when you forget to bring a card (proprietors walk morning and evening) to enter the elevator password; for visitors, without a card and password can be achieved ladder: first use the intercom system to call the household After the resident confirms the identity of the visitor, he presses the door open button and sends an activation signal to the elevator. The IC card elevator control system sends a signal that the guest can go to the floor. When the elevator goes down to the first floor, the guest enters the elevator and presses the resident office. If you press the button on the floor, you will register to start the elevator. On the other floors that are not authorized, visitors cannot register by pressing the button.
• The product has its own self-check device. When the system fails or is damaged, it can send a signal and it will be automatically detached from the original system to restore the original state of the elevator without affecting the use of the elevator.
• With power failure self-detection function, unexpected power failure can not only ensure the integrity of the data but also immediately leave the elevator automatically, so that the elevator can return to its original state to ensure safety;
• Having a fire signal input interface, when the passive dry contact fire switch signal is activated, the IC card elevator system does not work and the elevator is restored to its original state;
• The system core uses high-performance, low-power 32-bit industrial-grade ARM chips (ARM core that can quickly meet customer's individualized functional requirements;) and uses low-power CMOS microcomputers, and personnel and storage data at power-off can be preserved for 10 years. No loss • The unique blacklist management function of the system can be completed by swiping the card offline;
• Can be connected to multi-arc parking lot/access control/attendance/consume/channel/sub-systems, etc. Smart Card Main Equipment Specifications Max. operating current <480mA
Model Number: DAIC-DT-MB
Working current is about 120mA;
The main control board controls 16 layers and can be expanded according to the demand;
Each contact of the system is a passive dry contact input and output characteristic; one fire linkage input, 32 contact outputs;
On-resistance <3Ω;
Cut-off resistance greater than >20MΩ;
Operating environment: Temperature: -20--60°C
Relative humidity: 20% - 90% no condensation;
Cards used: The system uses Mifare® 1 card, typical operating time 0.2 seconds; card capacity is not limited CPU card elevator intelligent management system, a typical operating time of 0.3 seconds;
IC card elevator read head adopt capacitive touch type IC card elevator read head intelligent letter box (storage cabinet) system (optional)
Functional requirements are easy to operate: the user only needs to read the card (ID card or IC card) or enter the password, the box door automatically opens, the card can be shared with the property access card (card), and the password is set by the user.
2, high security: the use of radio frequency card and password technology, can not be deciphered, electronic control open, open box records can query.
High stability: With the application of mature intelligent technology, the electronically controlled lock is a special electromagnetic lock, the use of no fault, the internal circuit has been optimized, low energy consumption, stable and reliable. Power outage protection is normally used for 24 hours, and there are various emergency door open methods.
The exterior design is beautiful, the box body is made of high quality stainless steel plate, the structure is beautiful and elegant, and the customer's image is enhanced.
The main equipment technical parameters card format: IC card power supply: DC12V
Reading distance: 0-5CM
Working temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing)
The intelligent channel system function requirement 1 has a self-reporting fault prompt function, which is convenient for the user's use and maintenance;
2 has access instructions and channel indication functions;
3 Has normally open key function 4 with power swing open automatically, power on automatically closed function;
5 with line self-test function;
6 has an illegal intrusion alarm function;
7 has triple anti-pinch protection function;
8 access mode can be adjusted;
9 The time and mode of closing can be arbitrarily adjusted;
10 can be with Doo elevator / parking lot / access control / consumer / etc. smart card major equipment specifications card format: IC card power supply: DC12V
Reading distance: 0-5CM
Working temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing)
The intelligent electronic control system requires low power consumption of the energy meter, which is far less than the national standard requirements;
Anti-stealing function is strong. The single-phase electronic energy meter produced by our company adopts advanced anti-electricity stealing technology; it not only prevents ordinary meter stealing, external magnetic field, short circuit, reverse power, etc. The anti-electricity function of fire and ground;
With the timing method, you can flexibly set the rate and meet various requirements.
In terms of structure, there is an anti-stealing end cap designed to prevent short-circuiting and stealing;
With smart cards such as elevators/access control/consumption/channels;
The main equipment technical parameters card format: IC card power supply: DC12V
Reading distance: 0-5CM
Working temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing)
Billing accuracy: 0.01 yuan voltage line: ≤ 0.7W and 4VA (GB: ≤ 2W and 10VA)
The function of the parking guidance system requires the owner to know the current number of parking spaces on each floor of the parking lot through the display of parking spaces on the “outdoor LED parking space display†installed at the general entrance of the parking lot before driving into the parking lot;
After the vehicle enters the parking lot, it is located above the various intersections within the parking space, and an “indoor LED parking space display†is installed to show the current number of empty spaces in all directions leading to the junction;
A “parking light†is installed directly above each parking space. When the light is green, the parking space is empty. When the owner parks the vehicle in the empty parking space, the indicator light changes from green to red. Indicates that parking spaces have been parked;
After the vehicle is parked, outdoor and indoor LED parking spaces will automatically deduct 1 from the number of empty cars at the current location;
With smart cards such as elevators/access control/consumers/channels;
The main equipment technical parameters: light box + outdoor PH10 single red 3 16*32cm display module; installed near the ground entrance, showing the total remaining parking space information in one area, two areas and three areas. Video intercom system system function requirements The basic components can be divided into multi-storey buildings, small high-rises, high-rises and villas.
Usually, one community has a management center, and a large community consists of multiple communities. According to the actual situation and property management requirements, a main control center and multiple sub-control centers can be set up to facilitate the provision of quality services and work efficiency.
In terms of network construction, in order to improve the reliability of the system and enhance the system's resistance to external impact, we recommend the use of a three-tier switch as the core switching host for the community, and other high-quality second-tier and desktop switches to realize the number of the community. Exchange, transmission and other functions.
On the transmission material, the fiber-to-unit wiring method is adopted, and the single-mode optical fiber and the optical fiber transceiver are used for transmission, and inside the building, ultra-quinaline transmission is used.
Around the community, one or more residential wall machines are set up according to the actual situation on the site, which facilitates the identification of the identity of the external visitors and the management center or the owners; it is convenient for the owners to enter or leave the residential area to open or open the door remotely.
According to the needs of the customers in the community, the system can be expanded to provide extended services such as external network access and short message service.
With smart cards such as elevators/access control/consumers/channels;
Network transmission: simple construction, no interference, long transmission distance, no influence between backbones;
TCP/IP standard protocols, can share;
Major equipment technical parameters
Reserved Smart One Card Other Subsystem Interface Reserved English Version Software Interface Reserved Software SDK Interface to Campus One Card Management Software To facilitate the access of other systems, the card adopts an open architecture.
One card, one library, one software, one platform, it is not allowed to use multiple manufacturers, multiple softwares, multiple card dispensers, to integrate on one card, so that the true meaning of the intelligent management card, use the card because the elevator belongs to special equipment , Suppliers must provide real and effective special equipment test reports. Read heads look beautiful and generous with capacitive touch password keyboard. Suggested glass material. Closed management mode Video intercom system using pure digital TCP/IP mode Water control, electronic control , intelligent newspaper boxes in offline mode management center system <br> <br> overall system requirements:
One card, one library, one software, one platform, it is not allowed to use multiple manufacturers, multiple softwares, multiple card issuers, to integrate on one card, so that the true meaning of the intelligent management card, using a card.
Technical specifications of major equipment:
Power supply: external DC12V ± 5%;
Power input power: 2W;
Card reader module (Mifare® core module) model: MFRC500;
Working environment temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing);
The card type used is Miare® 1 card;
Reading and writing card distance: 0 ~ 5CM;
Reader and host computer communication: standard RS-232 asynchronous serial communication;
Communication parameters: baud rate: 115200bps; communication format: 1 start bit; 8 data bits; 1 stop bit; no parity bit; handshake: software handshake.
Access Control System System Function System Architecture: The network status can be operated offline in the event of a failure, and the fire-fighting linkage can be used to report the loss of cards.
Access control read head adopts capacitive touch password keyboard (unit intercom host uses embedded access control).
Households use a split plan.
Optional image capture and electronic map function, when the card is swiped, the image can be captured and saved, which can prevent the generation of swiping cards. (Internet access required)
It can flexibly set the cardholder's right to open the door, open the door, and open the door in the area to support multiple door opening methods: password, swipe card, remote door opening (networking required)
Can support multiple conditions and flexible combination of query access records, sort the report data in a different order, support for report data printing and export to the file function power lock power-down status can be key to open the door can be with multi-Olympic elevator / parking lot / channel / consumer / smart Card Main Equipment Specifications Operating Voltage: DC12V/1A
Working environment: -30°C-75°C
Communication method: RS485
Support card type: IC card, CPU card, etc. Intelligent Parking System Function Description Kernel uses ARM chip, I/O, control, etc. Integrated into a PCB board Nested partition management mode With remaining parking space Display temporary vehicle Automatic card output Anti-theft car entrance control machine with automatic card-out function (card out of abnormal situation when the card can be automatically recovered to prevent the loss of the card), unattended can be used to achieve automatic transfer of vehicles in and out images, capture, manual comparison of temporary card charges set Flexible, universal, support for multiple charging methods and elevator/attendance/access control/consumption/channel, etc. Smart Card Main Equipment Specifications Card Format: IC Card Power Supply: DC12V
Reading distance: 0-5CM
Working temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing)
The function of the intelligent consumption system requires that the consumption machine has the function of automatically recognizing "pseudo-cards", holding fake cards, fake cards, and those who have lost the cards, and the consumption machines will not be consumed.
Realize daily, monthly, yearly, and certain stages of the restaurant's daily report and monthly report records in detail. Various data can be seen at a glance at the desktop, and the hanging type can be converted to smart card main equipment technologies such as elevators/access control/consumers/channels. Parameter card format: IC card power supply: DC12V
Reading distance: 0-5CM
Working temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing)
Intelligent water control system function requires an integrated water control machine with electric valve, pulse water meter, lithium battery, controller integrated design, novel appearance, easy installation, tamper, anti-theft;
The operation is simple and does not require all kinds of complicated settings. One card, one card, the card is the withholding fee, the measurement is real-time and easy to use. After the card is deducted from the pre-charged water, the valve is opened and the valve is closed after the purchase of water.
Only single-cell lithium battery is used for power supply, and no external power supply is required for installation. It is convenient to replace the battery and is suitable for installation and use in dormitories and homes.
Battery box and body can be sealed to prevent malicious water theft;
When the amount of purchased water is used up, or when the battery is low, it prompts and automatically closes the valve;
Energy-saving design, using ultra-low-power chips, key trigger work, automatic sleep, effectively extending battery life;
Anti-theft, explosion-proof design, base table, base valve using high quality copper;
Anti-magnetic attack design, detecting magnetic interference can automatically close the valve;
The adjustable direction of the liquid crystal display makes it convenient for the user to view and display abundant information such as water consumption, remaining water amount, battery power, and valve switch status.
The equipment supports the use of cards to collect the remaining amount of water to the management software for the convenience of refunds and form changes.
Can be connected with elevators/access control/consumers/channels, etc. Smart Card Main Equipment Specifications Card Format: IC Card Issuer Capacity: Unlimited Operating Distance: >20mm
Working frequency: 13.56M
Read and write time: <1 second measurement accuracy: 1L
Data retention time: 10 years Battery life: 5 years Operating voltage: DC 3.7V
Ambient temperature: -5°C--50°C
Attendance intelligent management system (optionally equipped with source 2.4G remote automatic attendance system)
System function 1 Attendance system and access control system share employee basic database;
2 The employee's access record on the attendance machine is uploaded to the attendance computer and used directly for attendance;
3 has a password key function 4 with LCD display;
5 Query reports can be freely converted to EXCEL, TXT and web forms, user-friendly attendance reports and financial hooks, and remote web-based attendance reports sent over the Internet;
6 can print the attendance master list and schedule for any period of time, the item to be printed can be set by the user;
7 In the attendance overtime setting, you can freely set overtime start, end time, and overtime timing (usually the default is 1 overtime every half hour, the user can also be set arbitrarily) so that the employee can automatically read the overtime hours by swiping the card. recording. ;
8 Software records Store information such as the card number, job number, date and time, and validity of each employee's card attendance.
9 Optional image monitoring capture software, you can capture and save the image when swiping the card, the center management computer can display the swipe card image in time to prevent the card swiping or illegal card swiping. ;
10 can be with Doo elevator / parking lot / access control / consumer / etc. smart card major equipment technical indicators Power supply: AC220/50H
Working environment temperature: -35 degrees - +70 degrees Relative humidity: <95% non-condensing brushing distance: 5-10CM
Communication Interface: RS485 Optional TCP/IP
Support card types: IC card, CPU card, etc. Elevator IC card intelligent control system (for schools with elevators to prevent students from quaking eggs)
System functions • Control personnel in the elevator school box enter a specific floor. Control the access of cardholders to specific floors that are allowed in and out to prevent random access to all floors to ensure safety;
• The system and the elevator itself are passively connected. The two are completely isolated and will not affect the original performance of the elevator.
• Full port over-current, over-voltage, lightning protection, back pressure protection, instant over-voltage short-circuit protection, safe, stable and reliable;
• With section increment, delete, query card number and floor setting, you can set the elevator control such as holiday time permission setting by time;
• With time zone control: The system is opened for a certain period of time, controlled for a certain period of time, so that the elevator automatically runs according to regulations;
• Operation mode: Single-layer card (owner's card) Holder's credit card direct access. No need to press key; Multi-layered card (such as health management of aunts and patrolling security) after the user has swiped the card, it must be recorded according to the card. Permission keys to arrive; optional pure glass capacitive touch password keyboard, to achieve when you forget to bring a card (proprietors walk morning and evening) to enter the elevator password; for visitors, without a card and password can be achieved ladder: first use the intercom system to call the household After the resident confirms the identity of the visitor, he presses the door open button and sends an activation signal to the elevator. The IC card elevator control system sends a signal that the guest can go to the floor. When the elevator goes down to the first floor, the guest enters the elevator and presses the resident office. If you press the button on the floor, you will register to start the elevator. On the other floors that are not authorized, visitors cannot register by pressing the button.
• The product has its own self-check device. When the system fails or is damaged, it can send a signal and it will be automatically detached from the original system to restore the original state of the elevator without affecting the use of the elevator.
• With power failure self-detection function, unexpected power failure can not only ensure the integrity of the data but also immediately leave the elevator automatically, so that the elevator can return to its original state to ensure safety;
• Having a fire signal input interface, when the passive dry contact fire switch signal is activated, the IC card elevator system does not work and the elevator is restored to its original state;
• The system core uses high-performance, low-power 32-bit industrial-grade ARM chips (ARM core that can quickly meet customer's individualized functional requirements;) and uses low-power CMOS microcomputers, and personnel and storage data at power-off can be preserved for 10 years. No loss • The unique blacklist management function of the system can be completed by swiping the card offline;
• Can be connected to multi-arc parking lot/access control/attendance/consume/channel/sub-systems, etc. Smart Card Main Equipment Specifications Max. operating current <480mA
Model Number: DAIC-DT-MB
Working current is about 120mA;
The main control board controls 16 layers and can be expanded according to the demand;
Each contact of the system is a passive dry contact input and output characteristic; one fire linkage input, 32 contact outputs;
On-resistance <3Ω;
Cut-off resistance greater than >20MΩ;
Operating environment: Temperature: -20--60°C
Relative humidity: 20% - 90% no condensation;
Cards used: The system uses Mifare® 1 card, typical operating time 0.2 seconds; card capacity is not limited CPU card elevator intelligent management system, a typical operating time of 0.3 seconds;
IC card elevator read head adopt capacitive touch type IC card elevator read head intelligent letter box (storage cabinet) system (optional)
Functional requirements are easy to operate: the user only needs to read the card (ID card or IC card) or enter the password, the box door automatically opens, the card can be shared with the property access card (card), and the password is set by the user.
2, high security: the use of radio frequency card and password technology, can not be deciphered, electronic control open, open box records can query.
High stability: With the application of mature intelligent technology, the electronically controlled lock is a special electromagnetic lock, the use of no fault, the internal circuit has been optimized, low energy consumption, stable and reliable. Power outage protection is normally used for 24 hours, and there are various emergency door open methods.
The exterior design is beautiful, the box body is made of high quality stainless steel plate, the structure is beautiful and elegant, and the customer's image is enhanced.
The main equipment technical parameters card format: IC card power supply: DC12V
Reading distance: 0-5CM
Working temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing)
The intelligent channel system function requirement 1 has a self-reporting fault prompt function, which is convenient for the user's use and maintenance;
2 has access instructions and channel indication functions;
3 Has normally open key function 4 with power swing open automatically, power on automatically closed function;
5 with line self-test function;
6 has an illegal intrusion alarm function;
7 has triple anti-pinch protection function;
8 access mode can be adjusted;
9 The time and mode of closing can be arbitrarily adjusted;
10 can be with Doo elevator / parking lot / access control / consumer / etc. smart card major equipment specifications card format: IC card power supply: DC12V
Reading distance: 0-5CM
Working temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing)
The intelligent electronic control system requires low power consumption of the energy meter, which is far less than the national standard requirements;
Anti-stealing function is strong. The single-phase electronic energy meter produced by our company adopts advanced anti-electricity stealing technology; it not only prevents ordinary meter stealing, external magnetic field, short circuit, reverse power, etc. The anti-electricity function of fire and ground;
With the timing method, you can flexibly set the rate and meet various requirements.
In terms of structure, there is an anti-stealing end cap designed to prevent short-circuiting and stealing;
With smart cards such as elevators/access control/consumption/channels;
The main equipment technical parameters card format: IC card power supply: DC12V
Reading distance: 0-5CM
Working temperature: -25°C~45°C;
Working environment relative humidity: ≤ 90% (non-condensing)
Billing accuracy: 0.01 yuan voltage line: ≤ 0.7W and 4VA (GB: ≤ 2W and 10VA)
The function of the parking guidance system requires the owner to know the current number of parking spaces on each floor of the parking lot through the display of parking spaces on the “outdoor LED parking space display†installed at the general entrance of the parking lot before driving into the parking lot;
After the vehicle enters the parking lot, it is located above the various intersections within the parking space, and an “indoor LED parking space display†is installed to show the current number of empty spaces in all directions leading to the junction;
A “parking light†is installed directly above each parking space. When the light is green, the parking space is empty. When the owner parks the vehicle in the empty parking space, the indicator light changes from green to red. Indicates that parking spaces have been parked;
After the vehicle is parked, outdoor and indoor LED parking spaces will automatically deduct 1 from the number of empty cars at the current location;
With smart cards such as elevators/access control/consumers/channels;
The main equipment technical parameters: light box + outdoor PH10 single red 3 16*32cm display module; installed near the ground entrance, showing the total remaining parking space information in one area, two areas and three areas. Video intercom system system function requirements The basic components can be divided into multi-storey buildings, small high-rises, high-rises and villas.
Usually, one community has a management center, and a large community consists of multiple communities. According to the actual situation and property management requirements, a main control center and multiple sub-control centers can be set up to facilitate the provision of quality services and work efficiency.
In terms of network construction, in order to improve the reliability of the system and enhance the system's resistance to external impact, we recommend the use of a three-tier switch as the core switching host for the community, and other high-quality second-tier and desktop switches to realize the number of the community. Exchange, transmission and other functions.
On the transmission material, the fiber-to-unit wiring method is adopted, and the single-mode optical fiber and the optical fiber transceiver are used for transmission, and inside the building, ultra-quinaline transmission is used.
Around the community, one or more residential wall machines are set up according to the actual situation on the site, which facilitates the identification of the identity of the external visitors and the management center or the owners; it is convenient for the owners to enter or leave the residential area to open or open the door remotely.
According to the needs of the customers in the community, the system can be expanded to provide extended services such as external network access and short message service.
With smart cards such as elevators/access control/consumers/channels;
Network transmission: simple construction, no interference, long transmission distance, no influence between backbones;
TCP/IP standard protocols, can share;
Major equipment technical parameters
camera
CMOS digital color camera
Resolution
D1
Minimum illumination
0.2Lux (with luminous compensation lamp)
Fill light mode
White light
Display screen
4.3 inches, 16:9
Display pixels
480 × 272
Power supply
DC12V
Power consumption
Static: 2W; Max: 3.5W
Network Interface
RJ45
Transmission rate
10M / 100M
Operating temperature
-10 °C ~+ 50 °C
environment humidity
10% ~ 95%
Installation method
Embedded
Double Head Chamfering Machine
- Designed both inside and outside of the tube and rod end, chamfering and face milling can be done once a uniform, rapid and accurate.
- This Pipe Chamfering Machine has semi-automatic Type: artificial feed, automatic cutter speed of advance and retreat quickly, to replace parts of different sizes just to make a simple adjustment.
- Double head chamfering: cam synchronized feed, processing, high stability, can be done simultaneously on both sides, interior angle, exterior angle and the milling face at one time, can achieve a multiple increase in output.
- Gear chamfering machine can be appled to the material: stainless steel, iron, copper, aluminum tubing and bar.
Double Head Chamfering Machine,Cnc Gear Chamfering Machine,Double Side Chamfering Machine,Semi Automatic Double Chamfering Machine
GUANGDONG CHITTAK INTELLIGENT EQUIPMENT CO.,LTD , https://www.nbctkcutting.com